SMIHPL's service is presently limited to:
■ Loosening and tightening of Turbine Horizontal Joint (Parting Plane) Bolts.
■ Opening and closing of Generator Retaining Rings.
■ Generator / Alternator Slip Rings.
■ Shrunk Fitted Components, such as Couplings and Turbine Rotor Discs.
■ Stress Relieving of Welded Joint by Induction Heating.
■ Application of Induction Heating for rapid temperature increase in a material or a joint.
Site Requirements
Power Supply
■ Each machine requires minimum 415 volts 3 phase four wire (with neutral) supply at 150 amps.
Water Supply
■ Each machine requires a continuous water supply of 8 to 10 Gpm at 40 PSI
Our Equipment
■ 100 KW output power.
■ 3 to 10 kHz output frequency.
■ 52 inch (length) X 27 inch (width) X 54 inch (height).
■ 450 kg (weight).